13.Loosen the three camera enclosure mounting screws (see Fig. 5-8 below).

(recessed)

Fig. 5-8. Camera enclosure mounting screws

14.Set the camera height.

Insert the plain (non-stepped) end of the gauge as shown in Fig. 5-9 below.

Raise or lower the camera enclosure so that it touches the top of the gauge.

Camera enclosure

Fig. 5-9. Camera height measurement point

15.Tighten the camera enclosure mounting screws.

16.Replace carriage cover and screws.

17.Press ! to return the carriage to the service station.

The control panel displays a message asking whether you want to calibrate the service station. See “Calibrate the Ser- vice Station” on page 5-16 for instructions.

18.Press " to calibrate the service station, or ( to continue.

5-14

Set the Printhead and Camera Height

Page 144
Image 144
HP 72SR Camera enclosure mounting screws Set the camera height, Press to calibrate the service station, or to continue