Electrical Power

Power used: 200-240VAC, 50/60 Hz, 14.8 Amps

Required electrical circuit:

220 VAC, 20 Amps, with NEMA L6-20R locking wall receptacle (North America and Japan), OR 220 VAC, 16 Amps, single phase, with IEC 60309 wall receptacle (Europe)

NEMA L6-20R

IEC 60309

locking wall receptacle

wall receptacle

(North America/Japan)

(Europe)

North America: If your building receives power from a standard three-phase supply, note that the printer will use only two of the three phases. This means that your building’s three- phase power transformer may have an unbal- anced load. Check with your electrician to verify that your building has sufficient capacity for this unbalanced load.

Optional auxiliary power for vacuum system:

Supplied 24 volt DC power supply with univer- sal adapters, connected from the 24 VDC jack on the vacuum/pressure assembly to either of two options:

1.UPS customer-supplied uninterruptible power supply, output 100-240 VAC, 50/60 Hz, minimum of 15 watts of power, provides bat- tery backup to the vacuum system in the event of a power failure.

2.Wall outlet 100-240 VAC, 50/60 Hz, pro- vides temporary power to the vacuum system when it is necessary to power down the printer for service.

Specifications

A-3

Page 191
Image 191
HP 72SR manual Specifications, Required electrical circuit