HP General IO Connectivity manual Examples of the strace Command

Models: General IO Connectivity

1 269
Download 269 pages 25.18 Kb
Page 196
Image 196

Tracing and Logging Utilities strace

Table 7-9

(Continued)

 

 

 

 

 

FRMR Out

“Rsn 1” means the control field

 

 

received was not defined or not

 

 

implemented. “Rsn 3” means the

 

 

control field received was invalid.

 

 

“Rsn 4” means the information

 

 

field received was too long. “Rsn

 

 

8” means the control field

 

 

received contained an invalid

 

 

variable.

 

 

 

 

REJ In/Out (level 2)

“N(XX)” is an internal variable of

 

 

no importance or meaning.

 

 

 

 

LINK Bsy (level 2)

“Local” means that the RNR has

 

 

been sent. “Remote” means that

 

 

the RNR has been received.

 

 

 

Table 7-10

Output Format

 

 

 

 

 

 

 

 

X.25 level 1

 

a

Baud control (tx and rx counter)

 

(mod=210)

 

pri 0

 

 

 

pri 0

Baud control (threshold exceeded)

 

 

 

 

 

 

 

 

 

 

 

pri 0

Baud control (number of times threshold

 

 

 

 

exceeded)

 

 

 

 

 

a. pri = Logging priority level

Examples of the strace Command

To display all event messages from X.25 level 3 for all interfaces, use:

strace 200 all all

To display all event messages from X.25 level 3 for interface 0, use:

strace 200 48 all

To display event messages from X.25 level 3 with priority levels 1 to 3, and from X.25 level 2 with priority levels 1 and 2, use:

strace 200 all 3 201 all 2