Diagnostic Messages

 

 

 

 

 

X.25 Diagnostic Messages

Table C-7

International Problem and Maintenance (Continued)

 

 

 

 

 

 

 

121

 

Unknown

 

The CALL could not be routed because

 

(CLEAR)

 

called DNIC.

 

the DNIC in the called address is

 

 

 

 

 

unknown.

 

 

 

 

 

 

 

122

 

Maintenance

 

System administrator shut down

 

(CLEAR,

 

action.

 

specific VC or the entire interface.

 

RESET)

 

 

 

 

 

 

 

 

 

 

Table C-8

DTE-Specific Signals

 

 

 

 

 

 

 

 

 

Diagnostic

 

ISO

 

Explanation

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

160

 

DTE-specific

 

CALL INDICATION with reverse

 

(CLEAR,

 

signal

 

charge requested has been received,

 

RESET)

 

(generic).

 

and reverse charge is configured to be

 

 

 

 

 

rejected by system.

 

 

 

 

 

CALL INDICATION with reverse

 

 

 

 

 

charge requested has been received by

 

 

 

 

 

IP and reverse charge is configured to

 

 

 

 

 

be rejected for that IP/X.121 address

 

 

 

 

 

pair. Check is done via IP to X.121

 

 

 

 

 

address map table.

 

 

 

 

 

CALL INDICATION with reverse

 

 

 

 

 

charge requested has been received by

 

 

 

 

 

IP and no entry in the IP-to-X.121

 

 

 

 

 

address map table exists for this

 

 

 

 

 

X.121 address. Internal problem

 

 

 

 

 

which may be generated by

 

 

 

 

 

components of X.25/9000 architecture.

 

 

 

 

 

 

 

161

 

DTE

 

Level 2 is coming up or a SABM frame

 

(RESTART)

 

operational.

 

is received. System sends RESTART

 

 

 

 

 

REQUEST indicating host is up.

 

 

 

 

 

 

Appendix C

259

Page 259
Image 259
HP General IO Connectivity Table C-7 International Problem and Maintenance, Table C-8 DTE-Specific Signals Diagnostic