Table C-5

Call Setup, Call Clearing, or Registration Problem (Continued)

 

 

 

 

 

69 (CLEAR)

Invalid

Length of the facility field is greater

 

 

facility/

than the maximum allowed by the

 

 

registration

configured revision level of CCITT

 

 

length.

X.25 Recommendation (63 for 1980,

 

 

 

109 for 1984). The condition will result

 

 

 

in an error returned to the user

 

 

 

instead of generation of CLEAR if it is

 

 

 

detected in CALL REQUEST.

 

 

 

No combination of facilities can equal

 

 

 

the value indicated in the packet’s

 

 

 

facility length field. If this condition is

 

 

 

detected in the CALL REQUEST

 

 

 

packet it produces an error instead of a

 

 

 

CLEAR.

 

 

 

System could not add negotiation

 

 

 

facilities without the facility field

 

 

 

becoming larger than allowed by the

 

 

 

configured revision level of the CCITT

 

 

 

X.25 Recommendation (63 for 1980,

 

 

 

109 for 1984). This can happen only if

 

 

 

the configured negotiation facility

 

 

 

codes are not present in the facility

 

 

 

field.

 

 

 

 

 

70 (CLEAR)

Incoming

Configuration and status of interface

 

 

call barred.

disallows the opening of new inbound

 

 

 

connection.

 

 

 

 

 

71 (CLEAR)

No logical

No VC suitable for placing a

 

 

channel

connection in READY (P1) state.

 

 

available.

Generated when CALL REQUEST

 

 

 

cannot be completed successfully.

 

 

 

ENOSPC was returned to the caller if

 

 

 

condition was detected in synchronous

 

 

 

manner.

 

 

 

The number of internal connections

 

 

 

prohibits new connections being

 

 

 

allocated for CALL INDICATION.

 

 

 

 