Table A-2 Power and OL* LEDs

LED

Location

Driven By

State

Meaning

Cell Power

Chassis beside cell and

Cell LPM

Solid Green

HKP, PWR_GOOD

 

on cell

 

 

 

Cell Attention

Chassis beside cell

CLU

Solid

Cell OL*

 

 

 

Yellow

 

PDHC Post

Cell

PDHC

0x0

PDHC Post or run state

 

 

 

oxf

 

 

 

 

0xe->0x1

 

PM Post

On the UGUY board,

MOP

0x0

No HKP

 

driven by the PM

 

0xf

MOP is reset or dead

 

 

 

 

 

 

0xe->0x1

PM Post or run state

CLU Post

On the UGUY board,

SARG

0x0

No HKP

 

driven by the CLU

 

0xf

CLU is reset or dead

 

 

 

 

 

 

0xe->0x1

CLU Post or run state

PCI Card cage

Chassis behind PCI card

CLU

Solid

PCI card cage OL* LED,

Attention

cage

 

Yellow

 

Link Cable

Main Backplane

CLU

Solid

Link cable OL*

OL*

 

 

Yellow

 

MP Post

SBCH

SBCH

0x0

No HKP

 

 

 

0xf

MP is reset or dead

 

 

 

0xe->0x1

MP Post or run state

Cabinet and

Each fan

PM

Solid Green

Fan is running and no fault

IO Bay Fans

 

 

 

 

Backplane

System Backplane

RPM

Solid Green

Power supply is running

Power Boards

 

 

Yellow

Power fault

 

 

 

 

 

 

Blinking

 

Hot swap

System Backplane

RPM

Solid Green

HSO Supply running

oscillators

 

 

Solid

HSO clock fault

(HSO)

 

 

 

 

Yellow

 

 

 

 

 

146 sx2000 LEDs

Page 146
Image 146
HP Integrity Superdome and 9000 Superdome sx2000 manual Table A-2 Power and OL* LEDs, Mop