B Management Processor Commands

This appendix summarizes the management processor (MP) commands. In the examples, MP is used as the command prompt.

NOTE: The term Guardian Service Processor has been changed to Management Processor, but some code already written uses the old term.

BO Command

BO - Boot partition

Access level—Single PD user

Scope—partition

This command boots the specified partition. It ensures that all the cells assigned to the target partition have valid complex profiles and then releases Boot-Is-Blocked (BIB).

Example B-1 BO command

CA Command

CA - Configure Asynchronous & Modem Parameters

Access level—Operator

Scope—Complex

There is one active RS232 port connection to the service processor’s textual user interface. This RS232 connection is called the local RS232 port. The local RS232 port connects to a local terminal or to the CE laptop.

NOTE: On the HUCB board, there is a remote RS232 connector. The remote RS232 system was used to connect to a modem on legacy systems. Modem support is removed, so connections to the remote RS232 connector are ignored.

This command enables you to configure the local and remote console ports. The parameters you can configure are the baud rate, flow control, and modem type.

BO Command 149

Page 149
Image 149