Installing a flat panel monitor rack mount kit

You can store a T54 or T55 Flat Panel Monitor in a keyboard tray with the flat panel monitor rack mount kit. This kit requires an additional 2U of space above an installed keyboard tray in your rack cabinet. See the documentation that comes with the flat panel monitor rack mount kit for detailed installation instructions. Use the following general procedure to install a flat panel monitor in your rack cabinet:

Flat panel monitor

Rear screws

Mounting studs

Bumpers

Keyboard tray

Figure 45. Installing a flat panel monitor rack mount kit

1.Ensure that a keyboard tray is properly installed in your rack cabinet (see

“Keyboard tray” on page 101) with at least 2U of clearance above the keyboard tray.

2.Install the flat panel monitor base on the flat panel monitor. See the documentation that comes with your flat panel monitor rack mount kit for detailed installation instructions.

3.Install the mounting studs and bumpers on the keyboard tray.

4.Attach the monitor base to the inside of the keyboard tray using the screws that come with the rack mount kit.

5.Fold the monitor all the way down against the bumpers; then, slide the keyboard tray into the rack cabinet to ensure that there is proper clearance.

6.See the documentation that comes with your flat panel monitor for information on how to connect power and how to connect the monitor to a server or console switch.

Removing the existing flat panel monitor stand

Use the following steps to remove the existing flat panel monitor stand from your monitor:

NetBAY 42 Enterprise Rack (Type 9308 Models 42P, 42X, 4SA, 4SB, 42S, 42E) 103