/cfg/l3/vrrp/vrid 4/del /cfg/l3/vrrp/hot dis /cfg/l3/vrrp/group/dis
/* Configuration below for GbESM 2 (address .244) only
/cfg/l3/frwd/on
/cfg/l3/gw 1 addr 10.45.0.245 ena /cfg/l3/gw 2 addr 10.46.0.246 ena
/* create new vlans for uplink ports and reassign ports as needed /cfg/l2/vlan 45/ena
/cfg/l2/vlan 46/ena
/cfg/port ext1/tag dis /cfg/port ext2/tag dis /cfg/port ext3/tag ena /cfg/port ext5/tag dis /cfg/port ext6/tag dis
/cfg/l2/vlan 46/def ext1 ext2 /cfg/l2/vlan 45/def ext5 ext6
/cfg/l2/vlan 10/add ext3 /cfg/l2/vlan 20/add ext3
/cfg/l3/if 45 ena
vlan 45
addr 10.45.0.244 mask 255.255.255.0
/cfg/l3/if 46 ena
vlan 46
addr 10.46.0.244 mask 255.255.255.0
/* the below lines clean up unused items from the previous sample /cfg/vlan 46/del
/cfg/l3/if 46/del /cfg/l3/vrrp/vrid 3/del /cfg/l3/vrrp/vrid 4/del /cfg/l3/vrrp/hot dis /cfg/l3/vrrp/group/dis
128Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter