7.9 Configuration for Extreme switches
The configuration in Example
VLAN tagging using 802.1Q
Link aggregation (trunking) with static trunks; the Extreme switch did not support LACP.
RIP
Testing of the different variations of Spanning Tree Protocol was only partially successful. This is due to some limitations of the Extreme switch’s functionality as well as certain proprietary enhancements to the standards which the GbESM did not support. We were able to configure OSPF but not test it because an additional license which we did not have was required to enable this function.
Note that certain default configuration text was removed from the below due to extreme length. This test was present when we reset the switch to its factory defaults.
Example 7-42 Extreme switch configuration
# Full Detail Configuration
#
#
#Software Version 7.2e.1 (Build 10)
configure
configure
create vlan "VLAN20" create vlan "VLAN99"
#
# Config information for VLAN Default.
configure | vlan | "Default" tag 1 | # | |
configure | stpd | s0 add vlan "Default" |
|
configure vlan "Default" qosprofile "QP1"
configure vlan "Default" ipaddress 9.42.171.98 255.255.255.0 configure vlan "Default" add port 1 untagged
configure vlan "Default" add port 3 untagged configure vlan "Default" add port 4 untagged configure vlan "Default" add port 5 untagged configure vlan "Default" add port 6 untagged configure vlan "Default" add port 7 untagged configure vlan "Default" add port 8 untagged configure vlan "Default" add port 9 untagged configure vlan "Default" add port 10 untagged configure vlan "Default" add port 11 untagged
#similar lines for ports
#Config information for VLAN Mgmt.
#No IP address is configured for VLAN Mgmt.
#Config information for VLAN VLAN10.
configure vlan | "VLAN10" tag 10 | # | |
configure | stpd | s0 add vlan "VLAN10" |
|
configure | vlan | "VLAN10" qosprofile | "QP1" |
Chapter 7. Nortel Networks L2/3 GbESM configuration and network integration 143