switchport access vlan 45 ! -- vlan 46 on core 2

switchport trunk encapsulation dot1q switchport mode access

switchport nonegotiate

!

interface GigabitEthernet0/1 switchport access vlan 35 ! -- 36 on core 2

switchport trunk encapsulation dot1q switchport mode access

switchport nonegotiate channel-group 1 mode on

!

interface GigabitEthernet0/2 switchport access vlan 35 ! -- 36 on core 2

switchport trunk encapsulation dot1q switchport mode access

switchport nonegotiate channel-group 1 mode on

!

interface GigabitEthernet0/9 switchport access vlan 99 switchport mode access

!

interface GigabitEthernet0/11 switchport access vlan 45

! -- 46 on core 2

switchport trunk encapsulation dot1q switchport mode access

switchport nonegotiate channel-group 2 mode on

!

interface GigabitEthernet0/12 switchport access vlan 45

! -- 46 on core 2

switchport trunk encapsulation dot1q switchport mode access

switchport nonegotiate channel-group 2 mode on

!

!back door to ensure a working address to get in to the switch interface GigabitEthernet0/23

no switchport

ip address 10.56.0.245 255.255.255.0

!-- .246 on core 2

interface GigabitEthernet0/24 no switchport

ip address 9.42.171.245 255.255.255.0

!-- .246 on core 2

!

interface Vlan1

no ip address shutdown

!

!core 2 uses vlans 36 and 46 and addresses ending in .246