118 Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter
Example 7-25 Verifying operation of the Layer 3 configuration
/i/port
Alias Port Tag FAST PVID NAME VLAN(s)
----- ---- --- ---- ---- ------------- -----------------------
INT1 1 y n 20 INT1 1 4095 20
INT2 2 y n 1 INT2 1 4095 10 20
INT3 3 y n 10 INT3 1 4095 10
INT4 4 y n 1 INT4 1 4095
INT5 5 y n 1 INT5 1 4095
INT6 6 y n 1 INT6 1 4095
INT7 7 y n 1 INT7 1 4095
INT8 8 y n 1 INT8 1 4095
INT9 9 y n 1 INT9 1 4095
INT10 10 y n 1 INT10 1 4095
INT11 11 y n 1 INT11 1 4095
INT12 12 y n 1 INT12 1 4095
INT13 13 y n 1 INT13 1 4095
INT14 14 y n 1 INT14 1 4095
MGT1 15 y n 4095 MGT1 4095
MGT2 16 y n 4095 MGT2 4095
EXT1 17 n n 35 EXT1 35
EXT2 18 n n 35 EXT2 35
EXT3 19 y n 50 EXT3 10 20 50
EXT4 20 n n 1 EXT4 1
EXT5 21 n n 36 EXT5 36
EXT6 22 n n 36 EXT6 36
>> GbESM_1 - Information# /i/link
------------------------------------------------------------------
Alias Port Speed Duplex Flow Ctrl Link
----- ---- ----- -------- --TX-----RX-- ------
INT1 1 1000 full yes yes up
INT2 2 1000 full yes yes up
INT3 3 1000 full yes yes up
INT4 4 1000 full yes yes up
INT5 5 1000 full yes yes up
INT6 6 1000 full yes yes up
INT7 7 1000 full yes yes up
INT8 8 1000 full yes yes down
INT9 9 1000 full yes yes down
INT10 10 1000 full yes yes down
INT11 11 1000 full yes yes down
INT12 12 1000 full yes yes down
INT13 13 1000 full yes yes down
INT14 14 1000 full yes yes down
MGT1 15 100 full yes yes up
MGT2 16 100 full yes yes disabled
EXT1 17 1000 full no no up
EXT2 18 1000 full no no up
EXT3 19 1000 full yes yes up
EXT4 20 any any yes yes down
EXT5 21 1000 full no no up
EXT6 22 1000 full no no up
>> GbESM_1 - Information# /i/l2/trunk
Trunk group 1: Enabled
failover dis, port state:
EXT1: STG 1 forwarding
EXT2: STG 1 forwarding