/* the below is used solely to provide an unused VLAN as PVID for the crossover

/c/l2/vlan 50 ena def EXT3

/c/l2/stg 1/off /c/l2/stg 1/clear

/c/l2/stg 1/add 1 10 20 35 46 50 /c/l2/trunk 1

ena failovr dis add EXT1 add EXT2

/c/l2/trunk 2 ena failovr dis add EXT5 add EXT6

/c/l3/if 10 ena

addr 10.10.0.243

/* addr 10.10.0.244 on GbESM 2

mask

255.255.255.0

broad 10.10.0.255

vlan

10

/c/l3/if 20 ena

addr 10.20.0.243

/* addr 10.20.0.244 on GbESM 2

mask

255.255.255.0

broad 10.20.0.255

vlan

20

/c/l3/if 35 ena

addr 10.35.0.243

/* addr 10.35.0.244 on GbESM 2 mask 255.255.255.0 broad 10.35.0.255

 

vlan 35

/c/l3/if 46

 

ena

 

addr 10.46.0.243

/*

addr 10.46.0.244 on GbESM 2

 

mask 255.255.255.0

 

broad 10.46.0.255

 

vlan 46

/c/l3/if 50 ena

addr 10.50.0.243

/*244 on GbESM 2 mask 255.255.255.0

vlan 50

/c/l3/gw 1 ena

addr 10.35.0.245 /c/l3/gw 2

ena

Chapter 7. Nortel Networks L2/3 GbESM configuration and network integration 121

Page 135
Image 135
IBM L2/3 manual