/* the below is used solely to provide an unused VLAN as PVID for the crossover
/c/l2/vlan 50 ena def EXT3
/c/l2/stg 1/off /c/l2/stg 1/clear
/c/l2/stg 1/add 1 10 20 35 46 50 /c/l2/trunk 1
ena failovr dis add EXT1 add EXT2
/c/l2/trunk 2 ena failovr dis add EXT5 add EXT6
/c/l3/if 10 ena
addr 10.10.0.243
/* addr 10.10.0.244 on GbESM 2
mask | 255.255.255.0 |
broad 10.10.0.255 | |
vlan | 10 |
/c/l3/if 20 ena
addr 10.20.0.243
/* addr 10.20.0.244 on GbESM 2
mask | 255.255.255.0 |
broad 10.20.0.255 | |
vlan | 20 |
/c/l3/if 35 ena
addr 10.35.0.243
/* addr 10.35.0.244 on GbESM 2 mask 255.255.255.0 broad 10.35.0.255
| vlan 35 |
/c/l3/if 46 | |
| ena |
| addr 10.46.0.243 |
/* | addr 10.46.0.244 on GbESM 2 |
| mask 255.255.255.0 |
| broad 10.46.0.255 |
| vlan 46 |
/c/l3/if 50 ena
addr 10.50.0.243
/*244 on GbESM 2 mask 255.255.255.0
vlan 50
/c/l3/gw 1 ena
addr 10.35.0.245 /c/l3/gw 2
ena
Chapter 7. Nortel Networks L2/3 GbESM configuration and network integration 121