/cfg/l2/vlan 46/def ext5 ext6

/* for GbESM 2

/* /cfg/l2/vlan 35/def ext5 ext6 /* /cfg/l2/vlan 46/def ext1 ext2

/* both GbESMs use the below...

/cfg/l2/vlan 10/add ext3 /cfg/l2/vlan 20/add ext3

/* create L3 interfaces on VLANs

/* these are for the subnets where the servers are /cfg/l3/if 10

ena vlan 10

addr 10.10.0.243

/* addr 10.10.0.244 on GbESM 2 mask 255.255.255.0

/cfg/l3/if 20 ena

vlan 20

addr 10.20.0.243

/* addr 10.20.0.244 for GbESM 2 mask 255.255.255.0

/* these are for the uplink subnets /cfg/l3/if 35

ena vlan 35

addr 10.35.0.243 --

/* addr 10.35.0.244 for GbESM 2 mask 255.255.255.0

/cfg/l3/if 46 ena

vlan 46

addr 10.46.0.243

/* addr 10.46.0.244 for GbESM 2 mask 255.255.255.0

/* clean up VLAN 1 - remove unused ports /c/l2/vlan 1

rem EXT1 rem EXT2 rem EXT3 rem EXT5 rem EXT6

/* clean up VLAN 5 - unused in this configuration /c/l2/vlan 5

del

Chapter 7. Nortel Networks L2/3 GbESM configuration and network integration 113

Page 127
Image 127
IBM L2/3 manual