92 Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter
mask 255.255.255.0
broad 10.99.0.255
vlan 99
/c/l3/gw 1
ena
addr 10.99.0.245
/c/l3/gw 2
ena
addr 10.99.0.246
/c/l3/frwd/off
dirbr disabled
/
script end /**** DO NOT EDIT THIS LINE!
Example 7-14 Advanced Layer 2 Topology with PVST configuration for the Cisco3560 Switches
!
version 12.2
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname Core1
! hostname Core2 on Core2
!
enable password cisco
!
no aaa new-model
ip subnet-zero
ip routing
no ip domain-lookup
!
!
no file verify auto
!
spanning-tree mode pvst
no spanning-tree optimize bpdu transmission
spanning-tree extend system-id
spanning-tree vlan 1-10 priority 24576
! spanning-tree vlan 1-10 priority 28672 on Core2
spanning-tree vlan 11-4094 priority 28672
! spanning-tree vlan 11-4094 priority 24576 on Core2
!
vlan internal allocation policy ascending
!
!
interface Port-channel1
switchport trunk encapsulation dot1q
switchport trunk native vlan 5
switchport trunk allowed vlan 5,10,20,99
switchport mode trunk
switchport nonegotiate
!
interface Port-channel2
switchport trunk encapsulation dot1q
switchport trunk native vlan 5
switchport trunk allowed vlan 5,10,20,99