Re-enable the ports
After verifying the correct cabling between all the devices, the ports can be
Enabling the ports on GbESM_1 and GbESM_2
/oper/port EXT1/ena /oper/port EXT2/ena
Enabling the ports on Core1 and Core2
conf t
int range
After the ports have been enabled, the aggregated links should be functioning correctly. Example
Example
>>Layer 2# /i/l2/trunk Trunk group 1: Enabled failover ena, port state: EXT1: STG 1 forwarding EXT2: STG 1 forwarding
Complete configuration snapshots
Complete configuration files are shown for the GbESM (Example
Example
>> Main# /c/d |
|
|
script start | "Layer | |
er" 4 /**** | DO NOT EDIT THIS LINE! |
|
/* Configuration dump taken 13:44:45 Wed Jun 22, 2005 | ||
/* Version 1.0.1.6, Base MAC address 00:11:f9:36:b7:00 | ||
/* GbESM_1 |
|
|
/c/sys/ssnmp |
|
|
name | "GbESM_1" | /* name “GbESM_2” |
/c/port INT1 |
|
|
pvid | 20 |
|
/c/port INT3 |
|
|
pvid | 10 | /* pvid 20 |
/c/port INT4 |
|
|
pvid | 99 |
|
/c/port EXT1 |
|
|
tag ena |
| |
pvid | 5 |
|
/c/port EXT2 |
|
|
tag ena |
| |
pvid | 5 |
|
/c/l2/vlan 1 |
|
|
def INT1 INT2 INT3 INT4 INT5 INT6 INT7 INT8 INT9 INT10 INT11 INT12 INT13 | ||
INT14 EXT3 EXT4 EXT5 EXT6 |
| |
/c/l2/vlan 5 |
|
|
ena |
|
|
name | "Native" |
|
def EXT1 EXT2
/c/l2/vlan 10 ena
76Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter