Installation and Preparation
16
1. Connect the Power Cable.
Connect using the power cable supplied to an AC 220 V
- 240 V 50Hz/60Hz outlet.
2. Switch on the power switch on the rear panel.
The main power is turned on to initiate a system check.
The OPERATE LED will blink.
The OPERATE LED will then be steadily illuminated,
indicating that the OPERATE ON mode has been
activated. Operations are possible when the REC/STOP
mark appears on the on-screen menu.
1. Press the [OPERATE] button for at least two
consecutive seconds to move across to the OPERATE
OFF mode.
The OPERATE LED will be extinguished.
2. Switch off the power switch on the rear panel.
It is possible to switch between the operational mode
(OPERATE ON) and the stand-by mode (OPERATE OFF).
Press the [OPERATE] (when in the OPERATE OFF
mode.) button.
The OPERATE LED will blink.
The OPERATE LED will then be steadily illuminated,
indicating that the OPERATE ON mode has been
activated. Operations are possible when the date and
time appears on the on-screen menu.
* The OPERATE ON mode will be started up automatically
when the power switch on the rear panel is switched on.
Press the [OPERATE] button for at least two seconds
(when in the OPERATE ON mode.)
The OPERATE LED will blink.
A message stating “Please wait...” will be displayed.
The OPERATE OFF mode will then be activated, and the
OPERATE LED will be extinguished.
* Activate the OPERATE OFF mode before switching off
the power.
Set the OPERATE ON/OFF terminal to Low (0V) (when in
the OPERATE OFF mode.)
A system check will be started.
The OPERATE ON mode will then be activated.
Operations are possible when the date and time appear
on the on-screen menu.
Set the OPERATE ON/OFF terminal to Low (0V) (when
in the OPERATE ON mode.)
A message stating “Please wait...” will be displayed.
The OPERATE OFF mode will then be activated, and the
OPERATE LED will be extinguished.
* Activate the OPERATE OFF mode before switching off
the power.
Turning On/Off the Power

Switching the Power On

Switching the Power Off

Do not disconnect the power cable when the system
check is being run under any circumstances. Failure to
observe this may result in malfunctions.
CAUTION
It is recommended that a UPS (Uninterruptible Power
Supply) is used in consideration of power failures, etc.
(See System Connection on page 15)
(See Connecting a UPS on page 64)
MEMO
Switching between OPERATE ON/OFF with the button on the front panel

OPERATE ON

OPERATE OFF

Switching between OPERATE ON/OFF with the signal I/O terminal

OPERATE ON

OPERATE OFF