6. Setting up the [DURATION] setup screen.

*

Lists for which [DEL] have been set will be cleared before

 

the calculations are carried out.

*

Select [ABORT] and then press [SET] to abort the

 

 

Starting time

 

 

Ending time

 

 

 

 

 

 

DURATION

 

 

 

 

 

 

 

 

 

 

01

2005 / 10 / 01 10 : 01

2005 / 10 / 01 10 : 59

 

 

 

INPUT : 01 TYPE : ALL

2000MB [99]

DEL

 

 

 

 

 

 

02

2005 / 10 / 01 10 : 01

2005 / 10 / 01 10 : 59

 

 

 

INPUT : 09 TYPE : ALL

2000MB [99]

DEL

 

03

20

 

 

 

 

20

 

 

 

 

 

 

 

 

INPUT :

TYPE :

 

 

MB [ ]

DEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDIT

 

 

CHECK

 

 

 

EXPORT

 

 

 

 

 

 

 

 

 

 

Error message

4

5

 

 

display area

 

 

 

 

 

 

 

 

 

 

 

 

Capacity and chapters

Value display

1 2

Area to display the results of totaling calculations

Disk usage ratio

Total number of chapters

Total capacity

calculation process.

* Capacity calculation may require a certain amount of time

to run when the number of relevant chapters is large.

* Incorrect entries will be highlighted with red underlines.

„ It is possible to display a message stating [CAPACITY

OVER] on the [DURATION] setup screen when the capacity

exceeds the volume of the DVD (see the section on Error

Messages below.)

In this event, select [EDIT] on the [DURATION] setup

screen and press [SET] to amend or delete the period list

parameters.

1Select the required period list with the [S/T/W/X] keys, and then amend the value with the [–/+] keys. Starting Time: Specifies the starting date and time (yy/mm/

dd hh:mm) of the image data to be exported

Ending Time: Specifies the ending date and time (yy/mm/ dd hh:mm) of the image data to be exported

[INPUT] : Specifies the number of the camera that is to be exported.

[TYPE]: Specifies the type of recorded image data that is to be exported.

ALL

All images.

ALARM

Alarm recorded images taken with

 

alarm input.

M.DET

Alarm recorded images taken with the

 

motion detection function.

EMG

Emergency recorded images and

Capacity:

PASSCODE ERROR recorded images.

This field cannot be amended.

 

The results of capacity calculation are

 

displayed here. The number of chapters

 

taken during the period are displayed within

 

parenthesis. A message stating [OVER MB]

 

will be displayed if the capacity is too large.

 

[0 MB] will be displayed if no data exists for

[DEL]:

the relevant period.

Sets whether or not to delete the settings for

 

the relevant period list (this is used when a

 

capacity overflow occurs in the results of

 

capacity calculation.)

..............

Left undeleted

..............

Delete

2Press the [T] key to proceed onto the setup for the following list.

The cursor will move to the next list. Repeat the procedures explained in 1 .

3Press the [SET] button when all settings have been completed.

• Operations in the button area on the [DURATION] setup

screen will be activated.

4Select [CHECK] with the [W/X] keys, and then press [SET].

Calculation of the capacity for the setup lists will commence. A screen to indicate that calculations are in progress will be displayed.

When the calculation are complete, all of the period lists, the total capacity for the period lists, and the number of chapters will be displayed. The usage ration (percentage) of the disk will also be displayed.

5Select [EXPORT] with the [W/X] keys, and then press [SET].

The display will return to the live screen, and the export process will be commenced. The execution status of the export process will be displayed on the screen.

„Error Messages

Error messages similar to those shown below will be displayed in the error message display area when an error occurs with the parameters set on the [DURATION] setup screen.

INVALID DATE/TIME:

When one or more errors are included in the period setting.

CAPACITY OVER:

When excessive capacity exists in one or more period.

NO STREAM FOUND:

When relevant images do not exist in one or more period.

ERROR FOUND:

When an error other than those listed above exists in one or more period.

TOTAL CAPACITY OVER:

When an OVER CAPACITY error does not exist individually for each period, but when the total capacity exceeds 4.5GB.

ERROR: When an internal error occurs during export execution.

CHAPTER OVER:

When the number of chapters in one or more period are too many.

TOTAL CHAPTER OVER:

When an CHAPTER OVER error does not exist individually for each period, but when the total number of chapters exceeds a maximum of 498 when no audio sound is included, and a maximum of 249 when audio sound is included (the maximum limit for the number of chapters differs depending on the existence of audio sound.)

MEMO

Press the [RETURN] button when [EDIT], [CHECK] or [EXPORT] operations in the [DURATION] setup screen’s button area are activated to return to the previous screen.

Press the [CANCEL] or [MENU] button for several seconds to return to the live screen.

58

Page 58
Image 58
JVC VR-509E Setting up the Duration setup screen, Capacity, Del, Select Check with the W/X keys, and then press SET