ALARM Recording

Alarm recording is started when signals are input and when motion is detected in the STOP mode, and during normal recording and timer recording.

Emergency Recording

1.Connect the [EMERGENCY] terminal to the alarm device.

2.Setting the [DETAIL REC] screen. (Page 30)

Set the [EMERGENCY REC] setting to anything other than “OFF”.

3.Setting for the alarm terminal. (Page 33)

Select the camera that is to be used for emergency recording with the [EMERGENCY REC] setting.

4.Setting for the alarm recording. (Page 34)

Set the emergency recording time with the [DURATION] setting.

„Recording is started when a signal is input to the [EMERGENCY] terminal.

Alarm Recording (Signal Input Terminal)

1.Connect the [ALARM IN] terminal to the alarm device.

2.Setting the [DETAIL REC] screen. (Page 30)

Set whether alarm audio recording is to be activated or not with the [ALARM AUDIO REC] setting.

3.Setting for the Operation Set. (Page 31)

Set the [F.RATE (ips)] setting for [ALARM REC] to anything other than “---”.

4.Setting for the alarm terminal (Page 33)

Select the camera that is to be activated for the alarm input terminal.

5.Setting for the alarm recording (Page 34)

Set whether the alarm recording time and pre-alarm recording are to be activated or not.

„Recording is started when a signal is input to the [ALARM IN] terminal.

Alarm Recording (Motion Detection)

1.Setting the [DETAIL REC] screen. (Page 30)

Set whether alarm audio recording is to be activated or not with the [ALARM AUDIO REC] setting.

2.Setting for the Operation Set. (Page 31)

Set the [F.RATE (ips)] setting for [ALARM REC] to anything other than “---”.

Set the [M.DET] setting to anything other than “OFF”.

3.Setting for the alarm recording. (Page 34)

Set whether the alarm recording time and pre-alarm recording are to be activated or not.

Set the motion detection level.

4.Setting for the motion detection area. (Page 35)

„Recording is started when motions is detected in the input image.

Recording Camera Images

Setting up the ALARM TERMINAL

1.Press the [MENU] button.

The [MENU] → [REC DETAIL] → [ALARM TERMINAL] screens will be displayed in this sequence in accordance with the [MENU Screen Operations] explained on page 17.

 

ALARM TERMINAL

 

 

ALARM PORT

 

 

PORT1

(1)(-)(-)(-)(-)(-)(-)(-)(-)

 

 

PORT2

(-)(2)(-)(-)(-)(-)(-)(-)(-)

 

 

PORT3

(-)(-)(3)(-)(-)(-)(-)(-)(-)

 

 

PORT4

(-)(-)(-)(4)(-)(-)(-)(-)(-)

 

 

PORT5

(-)(-)(-)(-)(5)(-)(-)(-)(-)

 

2.

PORT6

(-)(-)(-)(-)(-)(6)(-)(-)(-)

 

 

PORT7

(-)(-)(-)(-)(-)(-)(7)(-)(-)

 

 

PORT8

(-)(-)(-)(-)(-)(-)(-)(8)(-)

 

 

PORT9

(-)(-)(-)(-)(-)(-)(-)(-)(9)

 

 

EMERGENCY REC (1)(2)(3)(4)(5)(6)(7)(8)(9)

The screen will display a matrix that shows the alarm input terminals on the vertical axis and the camera input on the horizontal axis.

If a camera input number is displayed on the right-hand side of the port number when a signal is input to each of

the alarm terminals it is enabled, and if [-] is displayed it is disabled.

*The corresponding camera input can also be set up for the emergency recording terminal in the same way.

2.Select your desired item with the [S/T/W/X] keys, and then change the value of the setting with [–/+].

Settings

ALARM PORT Corresponding Camera

(1), (2), (3), (4), (5), (6), (7), (8), (9):

Recording is started when a signal is input to the terminal.

[–]: Recording is not started even when signals are input to the terminal.

3.Press the [SET] button.

• The confirmation screen will be displayed.

4.Select [SAVE] with the [W/X] keys, and then press [SET].

MEMO

The [ALARM] indicator on the front panel will be illuminated during alarm recording and emergency recording. This will then blink when recording has finished.

A buzzer will sound during alarm and emergency recording if the [ALARM] setting on the [BUZZER] screen is set at “ON”. (See page 49)

Alarm recording and emergency recording will not be carried out when the setup menu is being displayed.

The recording frame rate will be the total number of frames divided equally into the value entered for emergency recording when emergency recording (passcode error recording) is in operation (Total frame count: See page 31).

33