Recording Camera Images

Setting the Operation Set (continued)

Procedure for Changing the Number of Cameras

1.Take a note of all the [OPERATION SET] data settings (F.RATE, QLY and M.DET on NORMAL REC/ALARM REC) when [STANDARD] or [REC PATTERN 1 to 9] is in use.

2.Amend the setting for the number of operation cameras with [INTRODUCTION SET] as explained on page 20.

3.When the [INTRODUCTION SET] parameters have been amended with procedure #2, reset the [OPERATION SET] data settings that were listed in procedure #1.

Operation Setup (RECOVERY REC, REC INDICATOR, REPEAT REC)

1.Press the [MENU] button.

The [MENU] → [DETAIL OPERATION] → [OPERATION SET] → [OPERATION] screens will be displayed in this sequence in accordance with the [MENU Screen Operations] explained on page 17.

OPERATION

 

 

 

RECOVERY REC

OFF

 

2.

REC INDICATOR

ON

 

 

REPEAT REC

OFF

 

 

OPELOCK RELEASE

BASIC

 

 

OPERATION LOCK

OFF

 

 

REC STOP

OFF

 

 

PLAY

OFF

 

 

CHANGE SETTING

OFF

 

 

CHANGE MONITOR

OFF

 

 

OPERATION

OFF

 

 

DVD

OFF

 

 

2.Select your desired item with the [S/T] keys, and then change the value of the setting with [–/+].

Settings

RECOVERY REC

Sets whether or not to perform recovery recording after a power

failure.

 

OFF:

Remains at OFF.

COMPULSION REC:Normal recording is started.

PRIOR STATE:

Recording is started in accordance with

 

the same settings prior to the power failure

 

only when recording was being carried out

 

before the power failure occurred.

REC INDICATOR

Sets whether or not to illuminate the recording indicator during

recording.

OFF: Not illuminated.

ON: Illuminated.

REPEAT REC

Sets the operations to be carried out when the hard disk runs out of space.

OFF: Recording is stopped.

ALARM LOCK:

Recording is continued while overwriting old recordings. However, the alarm log (including emergency and passcode error recording) will not be overwritten.

ALL: Recording is continued while overwriting all old logs. * Details on REPEAT REC are provided on page 104.

3.Press the [SET] button.

• The confirmation screen will be displayed.

4.Select “SAVE” with [W/X], and then press the [SET].

32

Page 32
Image 32
JVC VR-509E Operation Setup Recovery REC, REC INDICATOR, Repeat REC, Procedure for Changing the Number of Cameras