Recording Camera Images

Setting ALARM Recording

1.Press the [MENU] button.

The [MENU] → [REC DETAIL] → [ALARM REC] screens will be displayed in this sequence in accordance with the [MENU Screen Operations] explained on page 17.

ALARM REC

 

 

 

 

 

CAM NO

 

1

 

 

2.

 

 

DURATION

 

3MIN

 

3.

PREALARM REC

 

10SEC

 

MOTION DETECT SET

 

8

 

 

 

DYNAMIC SENSITIVITY LEVEL (DEFAULT-8)

 

 

 

STOP LEVEL

(DEFAULT-2)

2

 

 

 

TARGET AREA LEVEL

(DEFAULT-2)

2

 

 

 

MOTION DETECT AREA SET ..

 

 

 

 

 

2.Select the camera input that is to be set up with [W/X].

3.Select your desired item with the [S/T] keys, and then change the value of the setting with [–/+].

Settings

DURATION

10 SEC, 15 SEC, 30 SEC, 1 MIN, 3MIN, 5MIN:

Alarm recording is performed only for the period of time set.

MANUAL: Recording is continued during the period a signal is being input.

PREALARM REC

OFF: Pre-alarm recording is not performed.

10 SEC, 30 SEC, 60 SEC:

Pre-recording is performed only for the period of time set.

4.Press the [SET] button.

• The confirmation screen will be displayed.

5.Select [SAVE] with the [W/X] keys, and then press [SET].

*Pre-alarm recording is only performed for alarm detection when ALARM REC has been set and recording is not being carried out at that time.

Details on pre-alarm recording are provided on page 105.

*Alarm recording that includes motion detection will not be carried out when the setup menu is open.

Ending ALARM Recording

Alarm recording is stopped when [ALARM RESET] is pressed and when a signal is input to the [ALARM RESET] terminal during alarm recording (signal input terminal, motion detection.)

Canceling the Alarm with the Button on the

Front Panel

„Press [ALARM RESET] during alarm recording.

• Alarm recording will be stopped.

Canceling the Alarm with the Signal Input

Terminal

„Input a signal to the [ALARM RESET] terminal during alarm recording.

• Alarm recording will be stopped.

*Set the frame rate for [ALARM REC] at anything other than [--] for [INTRODUCTION SET-3] or [OPERATION SET] when alarm recording is to be carried out.

(Page 21, 31)

*There are cases where the search time during playback will require additional time if the number of alarms is increased. It is recommended that the formatting process is carried out when the number of alarms exceeds 100,000.

34

Page 34
Image 34
JVC VR-509E Setting Alarm Recording, Ending Alarm Recording, Canceling the Alarm with the Button on Front Panel