Setting the Operation Set

1.Press the [MENU] button.

Opens the menus in accordance with the instructions

provided in MENU Screen Operations (page 17) in the sequence of “MENU” → “DETAIL OPERATION” →

“OPERATION SET”.

OPERATION SET

STANDARD ..

REC PATTERN1 ..

REC PATTERN2 ..

REC PATTERN3 ..

REC PATTERN4 ..

REC PATTERN5 ..2.

REC PATTERN6 ..

REC PATTERN7 ..

REC PATTERN8 ..

REC PATTERN9 ..

2.Select your desired mode with [S/T], and then press the [SET] button.

The “REC PATTERN SET” screen will be displayed.

The amount of time that recording is possible in accordance with the set parameters will be displayed on the bottom line.

The amount of time recording is possible with the remaining hard disk capacity will be displayed when the [REPEAT REC] parameter is set at [OFF]. The amount of time recording is possible with the total capacity of the hard disk will be displayed when the [REPEAT REC] parameter is set at [ALL] or [ALARM LOCK].

 

3.

 

 

 

4.

 

 

 

 

 

 

STANDARD

 

 

 

 

 

 

 

 

 

 

NORMAL

REC

 

ALARM REC

 

 

 

 

 

 

 

F.RATE(ips)

QLY

 

F.RATE(ips) (AUTO) QLY

 

M.DET

CAM 1

8.3

 

N

 

8.3

H

 

OFF

CAM 2

8.3

 

N

 

8.3

H

OFF

CAM 3

8.3

 

N

 

8.3

H

OFF

CAM 4

8.3

 

N

 

8.3

H

OFF

CAM 5

8.3

 

N

 

8.3

H

OFF

CAM 6

8.3

 

N

 

8.3

H

OFF

CAM 7

8.3

 

N

 

8.3

H

OFF

CAM 8

8.3

 

N

 

8.3

H

OFF

CAM 9

8.3

 

N

 

8.3

H

OFF

RECORDABLE HOUR

 

42h

 

 

 

*The above is an example of STANDARD.

3.Select “NORMAL REC” with [S/T/W/X], and then select the frame count and resolution with [–/+].

Settings

F.RATE

0.08, 0.2, 0.4, 0.8, 1.7, 2.5, 5, 8.3, 12.5, 25:

Sets the number of frames (images) to be recorded per second.

---: Does not record.

QTY

 

 

 

 

 

H (High):

High resolution recording

N (Normal):

Normal resolution recording

B (Basic):

Basic resolution recording

L (Long):

Long-term resolution recording

Recording Camera Images

4.Select “ALARM REC” with [S/T/W/X], and then select “QTY” “F.RATE” or “M.DET” with [–/+].

Settings

F.RATE

0.8, 1.7, 2.5, 5, 8.3, 12.5, 25:

Sets the number of frames (images) to be recorded per second.

---: Does not record

(AUTO): Records with the highest frame count possible when there are no effects from other inputs.

Highest frame count: The maximum frame count that can be used for recording divided equally.

A guide to the estimated recordable frame rate is displayed on the right-hand side of the [AUTO] display when all alarm recordings have been started.

QTY

 

 

 

 

 

 

 

H (High):

High resolution recording

N (Normal):

Normal resolution recording

B (Basic):

Basic resolution recording

L (Long):

Long-term resolution recording

 

 

M.DET

 

 

 

 

 

 

Sets the M.DET sensitivity.

OFF:

Disables the M.DET mode.

NORM:

Detects the M.DET sensitivity in normal mode.

USER:

Detects the M.DET sensitivity in free mode.

DOOR H, DOOR L, HALL H, HALL L, CHECK H, CHECK L, ATM H, ATM L, LOBBY H, LOBBY L, GATE H, GATE L, PARK H, PARK L, DARK H, DARK L, ELEVATR, COUNTER:

Detects the M.DET sensitivity in set mode. * See page 35 for more details.

5.Press the [SET] button.

• A confirmation screen will be displayed.

6.Select “SAVE” with [W/X], and then press the [SET] button.

Restrictions on the Settings for Frame Rate

It is necessary to ensure that the total number of frames shown below in (1) to (3) are set so that they do not exceed 100 (or 50). The total number of frames are 100 when the [PRIORITY] setting on the [INTRODUCTION SET-1] screen (See page 20) is set at [SMOOTH], and 50 when it is set at [HIGH RESOLUTION].

(1)Total number of frames during normal operations.

(2)Total number of frames during alarm recording.

(3)Total number of frames of either each camera, normal operations or alarm operations, whichever is the largest.

31