Explanations

Repeat Recording

When recording reaches the end of the hard disk and there is no space left for recording, it returns to the start of the hard disk to overwrite old data. Such an operation is known as Repeat Record. Display the “OPERATION” in MENU Screen Operations to execute Repeat Rec mode. (Page 32)

OPERATION

 

 

 

 

 

 

 

 

 

RECOVERY REC

OFF

 

 

REC INDICATOR

ON

 

Set

REPEAT REC

OFF

 

 

 

 

OPELOCK RELEASE

BASIC

 

 

OPERATION LOCK

OFF

 

 

REC STOP

OFF

 

 

PLAY

OFF

 

 

CHANGE SETTING

OFF

 

 

CHANGE MONITOR

OFF

 

 

OPERATION

OFF

 

 

DVD

OFF

 

 

„When “ALARM LOCK” is selected

Executes repeat recording in the normal recording area (free space) excluding alarm recording data.

Beginning of

 

 

End of

hard disk

 

 

hard disk

Event1

Event2

Event3

Alarm1

Record

Record

Record

Record

Stops when there are too many alarm records and no space is left for the normal recording area.

Beginning of

 

 

End of

hard disk

 

 

hard disk

Alarm1

Alarm2

Alarm3

Alarm4

Record

Record

Record

Record

 

 

 

Recording

 

 

 

Stops

„When “ALL” is selected

Execute repeat recording regardless of alarm recording/ normal recording area.

Recording will continue lastingly until stopping the recording.

Beginning of

 

 

End of

hard disk

 

 

hard disk

Event1

Event2

Alarm1

Alarm2

Record

Record

Record

Record

Notes on Repeat Recording

The illustrations above on recording models are merely image diagrams and is different from the actual method of recording.

Repeat Record overwrites from the oldest event. Data that has been overwritten will be totally deleted.

There are cases where the deletion time for each channel does not match up.