RS-232C Interface

3. Details of the Commands (continued)

3.4.SENS Commands

ROM VER (72H) [JVC-1]

Returns the RS-232C software version. TXD 72H

RXD

21H

 

01H

 

10H

↓ ↓ ↓

RS-232C version is displayed

Ver.1-10 in the above example

STATUS SENSE (D7H) [BASIC/JVC-1]

Returns the status data related to the VR-509E in 11 bytes.

TXD

D7H

 

 

 

 

 

 

 

 

 

 

 

RXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st byte 2nd byte 3rd byte

 

 

 

11th byte

 

 

 

 

STATUS SENSE Return Data

 

 

 

 

 

 

 

 

 

 

byte No.

bit No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB STATUS

 

 

 

bit 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bit 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bit 5

 

Execution mode:

 

 

 

 

 

1

bit 4

 

00H : PB STOP

 

01H : PLAY

02H : STILL

bit 3

 

0BH : SHUTTLE FWD

 

0CH : SHUTTLE REV

 

 

 

 

bit 2

 

0DH : JOG FWD

 

0EH : JOG REV

 

 

 

bit 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bit 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC STATUS (Camera 1)

 

 

 

bit 7

 

Passcode error during REC, “1” output

 

 

 

bit 6

 

During emergency REC, “1” output

 

 

 

bit 5

 

During motion REC, “1” output

 

 

2

bit 4

 

During normal REC, “1” output

 

 

 

bit 3

 

During alarm REC, “1” output

 

 

 

bit 2

 

(Not defined) “0” output

 

 

 

 

 

 

bit 1

 

During pre-alarm REC, “1” output

 

 

 

bit 0

 

During time REC, “1” output

 

 

 

 

 

 

 

 

 

REC STATUS (Cameras 2 to 9)

3 to 11

bit7 to 0

Same content as the second byte (cameras 2 to 9)

DATE SENSE (BEH) [BASIC/JVC-1]

Returns the month, day and year currently set in the VR- 509E.

TXD BEH

RXD

Month Day Year

TIME SENSE (BFH) [BASIC/JVC-1]

Returns the hours, minutes and seconds currently set in the VR-509E.

TXD BFH

RXD

Hours Minutes Seconds

DEVICE TYPE (D1H) [JVC-1]

Returns the type of equipment connected to the VR-509E in ASCII code.

TXD

D1H

 

 

 

 

 

 

 

RXD

 

 

 

 

 

 

 

 

 

35H

 

30H

 

39H

 

49H

 

5

0

9

1

HOUR METER SENSE (D2H) [JVC-1] Returns the HOUR METER (time).

TXD D2H

RXD

6th character 4th character 2nd character

5th character 3rd character 1st character

NETWORK SENSE (D3H) [JVC-1] Returns the network setup data.

TXD

 

D3H

 

 

 

 

 

 

 

 

 

 

 

 

RXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st byte 2nd byte 3rd byte

33rd byte

 

 

 

 

NETWORK SENSE Return Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

byte No.

bit No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Host Name

 

 

 

1 to 16

bit 7 to 0

Host name (1st byte to 16th byte)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bit 7

Undefined (fixed at “0”)

 

 

 

 

bit 6

Undefined (fixed at “0”)

 

 

 

 

bit 5

Undefined (fixed at “0”)

 

 

 

17

bit 4

Undefined (fixed at “0”)

 

 

 

bit 3

Undefined (fixed at “0”)

 

 

 

 

 

 

 

 

bit 2

Undefined (fixed at “0”)

 

 

 

 

bit 1

Setup method: 00: Off, 01: Fixed, 10: DHCP

 

bit 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP Address

 

 

 

18 to 21

bit 7 to 0

IP address value (00H to FFH: 4BYTE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Net mask

 

 

 

22 to 25

bit 7 to 0

Net mask address value (00H to FFH: 4BYTE)

 

 

 

 

 

 

 

 

 

 

 

Gateway

 

 

 

26 to 29

bit 7 to 0

Gateway address value (00H to FFH: 4BYTE)

 

 

 

 

 

 

 

 

 

 

Name Server

 

 

 

30 to 33

bit 7 to 0

Name server address value (00H to FFH: 4BYTE)

119