Installation and Preparation
20
1. Press the [MENU] button.
Opens the menus in accordance with the instructions
provided in MENU Screen Operations (page 17) in the
sequence of “MENU” “INTRODUCTION SET”.
The “INTRODUCTION SET - 1” screen will be displayed.
* The settings cannot be amended during recording.
2. Select [Continue] on the confirmation screen with the
use of the [W/X] keys, and then press the [SET] button.
The confirmation screen will close.
* Select [ABORT] and press the [SET] button to return to
the top menu.
3. Select your desired item with [S/T], and then press
[–/+] to change the value settings.
Settings
CONNECT, DISCONNECT:
Sets the camera input that is to be used for
recording at “CONNECT”, and all other cameras
at “DISCONNECT”.
SMOOTH: Sets and records with a total recorded frame
count of 100 images per second, and a picture
size of 352 x 288 pixels.
HIGH-QUALITY:
Sets and records with a total recorded frame
count of 50 images per second, and a picture
size of 720 x 288 pixels.
4. Press the [SET] button.
The “INTRODUCTION SET - 2” screen will be displayed.
5. Select your desired item with [S/T], and then press
[–/+] to change the value settings.
Settings
1DAY, 3DAY, 5DAY, 1WEEK, 2WEEK, 3WEEK, 1MONTH,
2MONTH, 3MONTH:
Sets the period for which the recorded images are to
be stored on the hard disc based on the preset
recorded image mode and the number of cameras
connected.
* This storage period only acts as a yardstick, as the actual
period of storing images may differ depending on
amendments to the frame rate, resolution and other settings
in [INTRODUCTION SET-3] (refer to the section on recording
time on page 110 for further details on the storage period for
recorded images.)
ON, OFF: Sets whether to record sound audio when in the
NORMAL REC and ALARM REC modes.
Sets the action when the remaining capacity in the hard disk
becomes empty.
OFF: Stops recording.
ALARM LOCK:Conti nues recording over old recordings.
However, recordings made in the ALARM REC
mode will not be overwritten.
ALL: Co ntinues recording over old recordings.
Installation Settings

INTRODUCTION SET - 1

CAMERA1 to 9
PRIORITY
INTRODUCTION SET
DETAIL REC
DETAIL OPERATION
LIVE PICTURE
Button operation explanation
FUNCTION : USER GUIDANCE
SET UP
CURSOR
UPDATE/NEXT
BACK
3.
Confirmation
screen
2.
INTRDUCTION SET-1
CAM 1
CAM 2
CAM 3
CAM 4
CAM 5
CAM 6
CAM 7
CAM 8
CAM 9
PRIORITY
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
SMOOTH
CONTINUE
ABORT
The current setting is changed when preserving it.

INTRODUCTION SET - 2

DURATION
AUDIO REC
REPEAT REC
When the setting has been made for a specific number of
cameras, it is only possible to amend [INTRODUCTION
SET-1]. In order to amend the subsequent cameras, the
[OPERATION SET] data (the F, RATE, QLY, and M.DET
settings for NORMAL/REC/ALARM REC) that use
[STANDARD] or [REC PATTERN 1 to 9] must be reset.
(See “Setting the Operation Set” on page 31)
CAUTION
DURATION
AUDIO REC
REPEAT REC
INTRODUCTION SET-2
5 DAYS
ON
ALL 5.