Klark Teknik DN9340E, DN9344E Filters, To switch a Dynamic section out of the circuit, User Guide

Models: DN9344E DN9340E

1 65
Download 65 pages 57.17 Kb
Page 20
Image 20

HELIX DN9340E/DN9344E Remote Control Software

User Guide

To switch a Dynamic section out of the circuit

Dynamic switched out

1Tick the † Out check box at the bottom right-hand corner of its Dynamic control panel.

The Dynamic is faded to grey on the graph and its contribution is removed from the overall frequency response. The target remains active so that it can still be adjusted while switched out.

2To switch it in again, clear the check box.

5.4Filters

To switch to the Filter view

Click on the

Filter

button of the Channel A or B Navigation Strip, as required. (If staying on

the same Channel, you may prefer to click on a Filter tab).

The Filter freq, level, and Q are adjusted by dragging the ‘target’ or setting values

Control panels appear as you add Filters

Tick the check box to switch the filter out of the circuit

Filter Mode tab

The black graph shows overall response. The red graph shows the response of the selected LO or HI Dynamic

Filter Shaping tab

Choose a notch, pass or shelf filter

The upper Filter Mode tab is used to set the bypass state and the Graph display mode (when a DN9340) for the current channel. The lower Filter Shaping tab provides a control panel for each added Filter. Filter settings can also be adjusted at the display by using the target cursor.

20 of 65

Page 20
Image 20
Klark Teknik DN9340E Filters, To switch a Dynamic section out of the circuit, To switch to the Filter view, User Guide