HELIX DN9340E/DN9344E Remote Control Software
User Guide
The HELIX RCS will work through the ticked units in the list, setting each online in turn. As the download/upload takes some time to complete, the current progress is tracked by the status indicators to the right of the list while more specific progress remarks are displayed in the Comments column, for example, success or failed to go online. On completion, remember to relock the Preset Memories!
To Store/Recall settings to/from a specific Memory number, across multiple units
1 Switch to the Store \ Recall Memory tab.
Check the synchronise direction before starting the global recall/store
All or a subset of Units can be selected for updating
Either a User or Preset memory can be selected
Current progress is shown by the status bar
2 | Select the User or Preset Memory to be stored/recalled from the drop down list to the |
| right of the ‘tick list. |
Note
Settings cannot be stored to Preset memories on an individual basis; if you select a Preset Memory location, the Store button is faded out. To store a Preset memory you must use the write all command - this downloads each PC memory only to the equivalently numbered Unit Memory, thus providing an extra safeguard against accidentally overwriting essential settings.
3Tick the check box of each Unit that you wish to include in the store/recall.
4 | Set the Synchronisation to Get All Initial values from the Audio System or Set All Initial |
| values from Computer, as required. |
5Click
Recall From Memory
or
Store To Memory
as required.
The HELIX RCS will work through the ticked units in the list, setting each online in turn. Progress is tracked by the status indicators to the right of the list and more specific progress remarks are displayed in the Comments column.
To return to the FastNav® screen, click
Exit .
54 of 65