Table 6-1

Category

PC display status message

Trouble or status

 

Remedy

 

 

 

 

 

Controller errors

Controller Error

An error occured in the controller.

–

Normal operation cannot be

 

 

 

 

ensured.

 

 

 

 

Turn the power off, then back

 

 

 

 

on to restart.

 

 

 

– If normal operation is not

 

 

 

 

recovered by this restart

 

 

 

 

procedure, replace the Main

 

 

 

 

Control PCB.

 

 

 

 

 

 

Program ROM Check

An error was detected by program

–

Replace the Main Control PCB.

 

Error

ROM check.

–

When replacing the Main

 

 

 

 

Control PCB, upload/download

 

 

 

 

the EEPROM data. (Refer to

 

 

 

 

4.3.1-4.)

 

 

 

 

 

 

Font ROM Check Error

An error was detected by font ROM

–

Replace the Main Control PCB.

 

 

check.

–

When replacing the Main

 

 

 

 

Control PCB, upload/download

 

 

 

 

the EEPROM data. (Refer to

 

 

 

 

4.3.1-4.)

 

 

 

 

 

 

Resident RAM Check

An error was detected by resident

–

Replace the Main Control PCB.

 

Error

RAM check.

–

When replacing the Main

 

 

 

 

Control PCB, upload/download

 

 

 

 

the EEPROM data. (Refer to

 

 

 

 

4.3.1-4.)

 

 

 

 

 

 

EEPROM Check Error

An error was detected by EEPROM

–

Replace the Main Control PCB.

 

 

check.

–

When replacing the Main

 

 

 

 

Control PCB, upload/download

 

 

 

 

the EEPROM data. (Refer to

 

 

 

 

4.3.1-4.)

 

 

 

 

 

6 - 4