![](/images/new-backgrounds/1184205/184205185x1.webp)
4.3.2Adjustment When Replacing a Part (OKIPAGE6ex: 600dpi LED head) Adjustment is necessary when replacing any one of the following parts.
Parts | Required Adjustment |
|
|
LED head | LED head drive time |
| Head Type |
|
|
Image drum unit | Drum counter reset (Refer to the User's Manual.) |
|
|
Main Control Board | EEPROM data Upload/Download (See 4.3.1 4.) |
|
|
1Setting of LED Head Drive Time
Note: When the luminous intensity marking of the replacement LED head (new part) is same as that of the removed LED head (old part), do not set the LED head drive time.
• Luminous Intensity Marking Label
1224G2
7 3
or
Last 3 digits represent the LED head marking number.
401326
. . . . .
Luminous intensity marking
73000123400101100
or
027
403579
. . . . .
154
74000123400101100
4 - 14