![](/images/new-backgrounds/1184205/184205119x1.webp)
3.3.6Pulse Motor (Registration)
(1)Remove the upper cover (see 3.3.1).
(2)Remove the connector 3 from (CN3) 2 of the Main Control PCB 1.
(3)Remove two screws 4 and remove the pulse motor (registration) 6 from the motor bracket
5.
1
| 6 | |
4 |
| View A |
| ||
|
|
3
CN3
OKIPAGE 6e
2
4
CN3
OKIPAGE 6ex
5
3 - 12