5Fan error (ERROR 70)
•Is the fan rotating?
• Yes | Replace the Main Control PCB. |
▼
• No
• No
▼
• Yes
Is connector CN1 on the Main Control PCB being connected? Connect connector CN1.
Replace the fan or Main Control PCB (check coil resistance of the fan, See 7.3).
6 - 35