4.2Adjustment (OKIPAGE 6ex)

This chapter describes the adjustment necessary when replacing a part. The adjustment is made by changing the parameter value set in EEPROM on the Main Control PCB. The parameter can be set by the key operation from the operator panel. This printer has three kinds of maintenance modes, and it is necessary to select one of the modes when replacing a part.

4.2.1Maintenance Modes and Functions

1 User Maintenance Mode

This mode is being released to end-users, but it is rarely accessed.

To enter into the user maintenance mode, turn the POWER switch on while holding the MENU key down.

Function

There are following five functions:

Hex dump

Drum counter reset

Menu reset

Operator panel menu disable

X-adjust / Y-adjust

 

 

Detailed descriptions of these functions are provided in Appendix C, DIAGNOSTICS TEST.

2System Maintenance Mode

Note: This mode is used only by service persons and it should not be released to the end- users.

To enter into the system maintenance mode, turn the POWER switch on while holding the RECOVER key down.

Function

There are following five functions:

• Page count display

• Page count printing enable/disable • EEPROM reset

Rolling ASCII continuous printing

HIPER-W ENABLE/DISABLE

SIDM ENABLE/DISABLE

Detailed descriptions of these functions are provided in Appendix C, DIAGNOSTICS TEST.

4 - 10

Page 89
Image 89
Oki 6E specifications Adjustment Okipage 6ex, HIPER-W ENABLE/DISABLE Sidm ENABLE/DISABLE