Oki 6E, 6ex specifications Contd Category

Models: 6E 6ex

1 257
Download 257 pages 4.81 Kb
Page 105
Image 105

Table 6-1 (Cont'd)

Category

PC display status message

Trouble or status

Remedy

 

 

 

 

Controller errors

Optional Software ROM

An error was detected by optional

Check the optional software ROM

 

Check Error

software ROM check.

board for proper connection or

 

 

 

replace it.

 

 

 

 

 

Optional RAM Check

An error was detected by optional

– Check the optional RAM board

 

Error

RAM check.

for proper connection.

 

 

 

– Check the mounting position of

 

 

 

short plugs and additional RAM

 

 

 

chips. (See 7.4.)

 

 

 

– Replace the optional RAM board.

 

 

 

 

 

FAN Motor Error

A fault occured in the fan motor.

– Check the fan motor for proper

 

 

 

connection and for any presence

 

 

 

of foreign matter in the fan.

 

 

 

(See 6.5.2-5.)

 

 

 

– Replace the fan motor or the

 

 

 

Main Control PCB.

 

 

 

 

 

Fuser Error

A fault occured in the fusing unit.

See 6.5.2-4.

 

 

(Timeout error, etc.)

 

 

 

 

 

 

Thermistor Open Check

A fault occured in the fusing unit.

See 6.5.2-4.

 

Error

(Thermistor open check error)

 

 

 

 

 

 

Thermistor Short Check

A fault occured in the fusing unit.

See 6.5.2-4.

 

Error

(Thermistor short check error)

 

 

 

 

 

 

SSIO Interface Error

Power supply board SSIO I/F error

Replace the power supply board or

 

 

 

the Main Control PCB.

 

 

 

 

6 - 5

Page 105
Image 105
Oki 6E, 6ex specifications Contd Category