Oki 6ex, 6E specifications Sync

Models: 6E 6ex

1 257
Download 257 pages 4.81 Kb
Page 180
Image 180

Appendix B LOCALTALK (RS422) SERIAL INTERFACE

1) Connector

 

 

• Printer side

:

8-pin mini DIN receptacle

 

 

Type TCS7187-01-201 (made by HOSHIDEN) or equivalent

• Cable side

:

8-pin mini DIN plug

 

 

Type TCP7180-01-110 (made by HOSHIDEN) or equivalent

2)Cable

To be shielded cable

Cable length LocalTalk

Defined max. length

:

1,000 ft. (305 m) (It is the maximum length for a

 

 

LocalTalk network.)

Recommended max. length :

10 ft. (3 m) (For noise prevention)

 

RS422 : 6 ft. (1.8 m) max.

 

 

3)

Interface signal

 

 

 

 

 

 

 

 

Pin No.

Signal Name

Abfreviation

Signal Direction

Description

 

 

 

 

 

1

 

 

(Not used)

 

 

 

 

 

2

Sync. signal

SYNC

PR

(Not used)

 

 

 

 

 

3

Transmit data minus

TxD-

PR

Transmit data minus polarity

 

 

 

 

 

4

Signal ground

SG

 

Signal ground

 

 

 

 

 

5

Receive data minus

RxD-

PR

Receive data minus polarity

 

 

 

 

 

6

Transmit data plus

TxD+

PR

Transmit data plus polarity

 

 

 

 

 

7

 

 

(Not used)

 

 

 

 

 

8

Receive data plus

RxD+

PR

Receive data plus polarity

 

 

 

 

 

B - 1

Page 180
Image 180
Oki 6ex, 6E specifications Sync