Note: The bias voltage required during the developing process is supplied to the toner supply roller and the developing roller, as shown in the diagram below. –450 VDC is supplied to the toner supply roller, –300 VDC to the developing roller.

Connected and bias supplied when the cover

is closed

Toner supply roller

Developing roller

Base

Image drum

2 - 23