Chapter 3. System Features Section 700 - Operation Page 3-52 DBS Manual - Revised April 2000 DBS-2.3/9.2-700Figure 2-2. SMDR Format for CPC-AII and CPC-B Version 3.1 or higher
0 1 2 3 4 5 6 7
012345678901234567890123456789012345678901234567890123456789012345678901234567
1 2 3 4 5 6 7 8 9
T MM/DD HH:MM:SS HH:MM.SS NNN DDDDDDDDDDDDDDDDDDDDDDDDDDDD AAAAAAAAAA VVVVV NN
1=Call type
S=Inbound DISA
s=Outbound DISA
I=Incoming
O=Outgoing
T=Transfer (See Note 1.)
N=DNIS
D=DID
2=Date
MM=month
DD=day
3=Call start time
HH=hours
MM=minutes
SS=seconds
4=Call duration
HH=hours
MM=minutes
SS=seconds
5=Extension number
10-69, 100-699=extensions
CO number=DISA
6=Dialed digits or Caller ID
DD=digits 0-9 or symbols * or #
(See Note 2.)
7=Account code
A=0-9999999999
8=Verified account code or walking
COS code
V0000-V9999=verified account cod es
W0000-W9999=walking COS codes
9=Trunk Number
NN=number (01-64)
Notes:
1. Transferred calls include direct and group call pickups and conference calls.
If a station call is transferred to an outside number, an SMD R re co rd is
also created for the station that is transferred.
2. The * symbol appears as a greater-than sign (>) on the SMDR printout; the # symbol
appears as a less-than sign (<). Cent rex and PBX codes, as well as LCR access codes, do
not appear as dialed digits. If th e Caller ID Feature is installed and enabled,
“Private” appears with calls that have restric te d Ca ll er ID di sp la y an d “O ut of Ar ea ”
with long distance calls that do not provide Caller ID information.