Section 700 - Operation Chapter 3. System Features
DBS-2.3/9.2-700 DBS Manual - Revised April 2000 Page 3-53
Figure 2-3. SMDR Format for CPC-A and CPC-B Versions Prior to 3.1
Related Programming
FF1 (System): Parity Check
FF1 (System): Odd/Even Parity
FF1 (System): Baud Rate
FF1 (System): Stop Bit Length
FF1 (System): Data Length
FF1 (System): Serial Port Flow Control (X On/ X Off)
FF1 (System): SMDR Display Start Timer for CO Calls
FF1 (System): SMDR Printing Mode 1: Outbound and Inbound
FF1 (System): SMDR Printing Mode 2: Long Distance and Local Calls
FF1 (System): SMDR Printing Mode 3: Header Title
FF3 (Extension) Station Message Detail Recorder (SMDR) Report
Hardware Requirements
A printer or external call ac counting system is required to receive SMDR
data.
0 1 2 3 4 5 6 7
01234567890123456789012345678901234567890123456789012345678901234567890
1 2 3 4 5 6 7 8
MM DD HH:MM H:MM.X C NN DDDDD-DDD-DDD-DDDD NNN AAAAAAAAAA
1=Date
MM=month
DD=day
2=Call start time
HH=hour
MM=minute
3=Call duration
H=hour (0-9)
MM=minutes
X=1/10th of a minute (0-9)
4=Call condition
I=incoming
i=DISA incoming
O=DISA outgoing
D=Call longer than 10 hours
5=Trunk number
NN=number (01-64)
6=Dialed digits
DD=digits 0-9 or symbols * or #
(See the Note following item 8.)
7=Extension number or DISA number
10-73, 100-699=extensions
#01-#64=DISA numbers
8=Account code
A=digits 0-9 or symbols * or #
Note: The * symbol appears as a
greater-than sign (>) on the SMDR
printout; the # symbol appears as a
less-than sign (<).