13 Configure the alarm settings [Alarm]
[Terminal 3]
Determine how to use terminal 3.
•Off: Not used.
•Alarm input: Receives alarms. When “Alarm input” is selected, a
–Close: An alarm is detected when the terminal status is changed to “Close”.
–Open: An alarm is detected when the terminal status is changed to “Open”.
•AUX output: AUX output will be supplied. The [AUX] buttons will be displayed on the “Live” page.
•Default: Off
IMPORTANT
•In order for the EXT I/O terminals to detect alarm inputs when the terminal status is changed from Open to Close (On) or from Close to Open (Off), about 100 ms or more is needed. Because alarms cannot be detected for about 5 seconds after a detection is made, alarm inputs received within about 5 seconds after an alarm is detected are not detected.
Note
•AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page. For example, an operator can remotely control lights in a place where the camera is installed by connecting the terminal to the light controller.
•Refer to the Installation Guide for further information about input/output rating of each terminal.
[VMD alarm]
When clicking “VMD >>”, the [VMD area] tab of the “Alarm” page will be displayed. (→page 134)
[Command alarm]
Select “On” or “Off” to determine whether or not to receive the command alarm.
The command alarm is the function that provides notification of a Panasonic protocol alarm from the other cameras. When “On” is selected, alarm actions will be performed between multiple cameras.
•Default: Off
[Originating port number]
Select a port number to be used to receive the command alarm.
•Available range: 1-65535
•Default: 8181
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670,
13.2Configure the settings relating to the alarm image [Alarm]
Click the [Alarm] tab on the “Alarm” page. (→page 51, page 53)
The settings relating to the alarm image to be transmitted to an FTP server can be configured in this section. The alarm image will be transmitted to an FTP server. To transmit alarm images to an FTP server, it is necessary to configure the settings in advance. (→page 150)
IMPORTANT
•Depending on the network line speed or the network traffic, images may not be transmitted at the exact designated interval or period.
126