Fuse Configuration

The main fuse(s) on the Paxar 545 are located inside the AC entry. The entry has a fuse drawer that holds the fuse(s) and selects the appropriate line voltage. If the voltage in the window DOES NOT match the AC line amplitude intended to be supplied to the printer, DO NOT plug the power cord in. Reconfigure as follows:

1)Using a flat blade screwdriver, open the AC entry by lifting the tab just above the voltage indicator window.

AC Entry

2) Remove the red fuse drawer.

3)Remove all fuses and the fuse jumper if it is present.

4)Insert into the fuse drawer the correct number and style of fuse(s) and fuse jumper for your application.

Configuration Number One:

Line voltage within the range of

(See 115VAC Fuse Placement)

90 - 132VAC @ 50 - 60Hz

1)Install one 990689 – 6.25A 250V Fast Acting 1/4 x 1 1/4"

2)Install one Fuse Jumper