Q-Logic FIRMWARE VERSION 7.4 manual Configuring Port Alarm Thresholds

Models: FIRMWARE VERSION 7.4

1 84
Download 84 pages 32.06 Kb
Page 13
Image 13

A

2 – Events and Event Logging Configuring Port Alarm Thresholds

Configuring Port Alarm Thresholds

You can configure the switch to generate alarms for selected events. Configuring an alarm involves choosing an event type, rising and falling triggers, a sample window, and finally enabling or disabling the alarm. You can configure port alarm thresholds for the following port events using Enterprise Fabric Suite 2007 or the CLI:

„Cyclic Redundancy Check (CRC) errors

„Decode errors

„Inter-switch Link (ISL) connections

„Device logins

„Device logouts

„Loss-of-signal errors

To configure port threshold alarms using Enterprise Fabric Suite 2007, do the following:

1.Open the Switch menu in the faceplate display, and select Port Threshold Alarm Configuration.

2.The Port Threshold Alarm Configuration dialog prompts you to enable or disable all alarms, select an event, set triggers, set a sample window and enable or disable an individual alarm. For more information, refer to the Enterprise Fabric Suite 2007 User Guide for your switch.

To configure port threshold alarms using the command line interface, use the Set Config Threshold command. For more information, refer to the Command Line Interface Guide for your switch.