3 – Event Messages Critical Events

S

(C)(8400.0069) (Switch) (Warning-When leaving the Diagnostics AdminState of the primary CPU blade, an automatic reset of the blade will occur. The blade and the switch will come back up in the configured AdminState.)

Meaning:

The primary CPU blade is entering Diagnostics state and will

 

automatically undergo a hard reset. The I/O blade will return to the

 

configured administrative state after leaving the Diagnostics

 

administrative state.

(C) (8400.006A) (Switch) (Upgrading License for Fabric Security)

Meaning:

The Fabric Security Bundle license was applied successfully.

(C) (8400.006B) (Switch) (Upgrading License for CLI Extended Credits capability)

Meaning:

The CLI Extended Credits license was applied successfully.

(C) (8400.0070) (blade_ID blade is operational)

Meaning:

The specified blade is powered on and fully operational.

(C) (8400.0071) (Extraction latch was opened)

Meaning:

The latch has been pulled down. The blade is not accessible.

(C) (8400.0072) (Extraction latch was closed)

Meaning:

The latch has been closed. The blade is inserted into the chassis.

(C) (8400.0073) (Blade was powered off)

Meaning:

The blade is powered off after a latch pull.

(C) (8400.0074) (Blade was powered on)

Meaning:

The blade was powered on after an extraction latch was closed.

(C) (8400.0075) (Upgrading License for Fault Tolerant capability)

Meaning:

The Fault Tolerant license was applied successfully.

(C) (8400.0076) (Upgrading License for HyperStack(tm) capability)

Meaning:

The HyperStack license was applied successfully.

(C) (8400.0079) (Canceling config edit mode as a result of a CPU switchover)

Meaning:

A CPU blade switchover occurred while a Config Edit session was

 

open.

(C) (8400.007A) (Resaving the zoning config as a result of a CPU switchover)

Meaning:

A CPU blade switchover occurred while saving the configured

 

zoning database. A save ‘retry’ is occurring.