3 – Event Messages Alarm Events

S

(A1003.0069) (Failing remote zoning configuration, invalid zone data received)

Meaning:

Zoning activation failed because the switch detected invalid zoning

 

data that is not supported in the local interop mode.

Action:

Check your zoning configuration and remove incompatible zone

 

members.

(A1004.0001) (Port in active hard zone, but not installed or present on this switch.)

Meaning:

A zone member in an ACL zone on this switch is defined with an

 

invalid port number.

Action:

Examine the fabric and correct the zone membership.

(A1004.0005) (No communication from neighbor switch on port port_number with domain ID domain_ID, lost route)

Meaning:

This switch has not received a hello from the remote switch for 80

 

seconds. The routes learned through this link are discarded.

Action:

None

(A1004.0008) (Eport Isolating due to ELP Incompatibility)

Meaning:

An E_Port isolated due to an ELP (Exchange Link Parameter)

 

incompatibility.

Action:

Review the accompanying alarms for a specific cause.

(A1004.0009) (Eport Isolating due to ESC Incompatibility)

Meaning:

An E_Port isolated because the connecting switch failed to support

 

the standard routing protocol FSPF.

Action:

Connect a compatible switch.

(A1004.000A) (Eport Isolating due to EFP Domain Overlap)

Meaning:

An E_Port isolated because each fabric has a switch with the same

 

domain ID.

Action:

Change the domain ID on one of the conflicting switches.

(A1004.000B) (Eport Isolating due to Switch Administratively Offline)

Meaning:

An E_Port isolated because the local switch has been placed

 

offline.

Action:

Configure the administrative state to Online to establish the link.

3-14

59060-05 A

Page 28
Image 28
Q-Logic FIRMWARE VERSION 7.4 manual A1004.0008 Eport Isolating due to ELP Incompatibility