A

3 – Event Messages Alarm Events

(A2000.0004)

(power_supply_number AC power may be unplugged or switched off -

 

ALARM SET)

 

 

Meaning:

One of the two power supplies is not receiving power.

 

Action:

Check the switch power supply and the AC power source.

(A2001.0001)

(Pwr2 was installed - ALARM CLEARED)

 

Meaning:

Power supply #2 was installed.

 

Action:

None

(A2001.0002)

(Pwr1 OK - ALARM CLEARED)

 

Meaning:

Power supply OK.

 

Action:

None

(A2001.0004)

(power_supply_number AC power is good - ALARM CLEARED)

 

Meaning:

AC power has been restored.

 

Action:

None

(A2002.0001)

(fan_number was removed)

 

Meaning:

A field replaceable fan was removed from the switch.

 

Action:

Reinstall the fan.

(A2002.0002)

(Fan fan_blade failure - ALARM SET)

 

Meaning:

A cooling fan has failed.

 

Action:

Replace the fan if it is a customer replaceable unit. Otherwise,

 

 

contact your authorized maintenance provider.

(A2002.0003)

(Fan or power supply flow mismatch - ALARM SET)

 

Meaning:

The switch has two cooling fans with opposite air flow directions.

 

Action:

Replace one of the fans with another fan with the correct air flow

 

 

direction.

(A2003.0001)

(fan_blade inserted - ALARM CLEARED)

 

Meaning:

The switch fan blade has been installed and the alarm is cleared.

 

Action:

None

(A2003.0002)

(fan_blade OK - ALARM CLEARED)

 

Meaning:

The switch fan blade is operational and the alarm is cleared.

 

Action:

None

59060-05 A

3-41

Page 55
Image 55
Q-Logic FIRMWARE VERSION 7.4 manual Alarm SET