Q-Logic FIRMWARE VERSION 7.4 manual A1005.0074 Blade seating is questionable

Models: FIRMWARE VERSION 7.4

1 84
Download 84 pages 32.06 Kb
Page 44
Image 44

3 – Event Messages Alarm Events

S

(A1005.0074)

(Blade seating is questionable)

 

Meaning:

A SANbox 9000 blade is improperly installed.

 

Action:

Examine the switch and reinstall blades as needed.

(A1005.0075)

(Blade seating problem was resolved)

 

Meaning:

The SANbox 9000 blade seating problem as resolved.

 

Action:

None

(A1005.0076)

(Extraction latch is open)

 

Meaning:

A SANbox 9000 blade latch is open.

 

Action:

Examine the switch and close open latches.

(A1005.0077)

(Extraction latch was closed)

 

Meaning:

The SANbox 9000 blade latch has been closed.

 

Action:

None

(A1005.0078)

(Extraction latch ignored until hotreset completes)

 

Meaning:

Extraction latch was opened while a switch hot reset was in

 

 

progress.

 

Action:

Return the extraction latch to the closed position. Wait until the hot

 

 

reset is complete, then remove the blade.

(A1005.0079) (Blade fault fault reported from primary CPU, resetting switch)

Meaning:

A blade fault has occurred on the SANbox 9000 primary CPU

 

blade and the switch is resetting.

Action:

Contact your authorized maintenance provider.

(A1005.007A) (Blade fault fault reported from primary CPU, powering off blades/ports)

Meaning:

A blade fault has occurred on the SANbox 9000 primary CPU

 

blade. I/O blades are being powered down.

Action:

Contact your authorized maintenance provider.

(A1005.007C) (Secondary CPU's latch is closed so now able to become Fault Tolerant)

Meaning:

The SANbox 9000 secondary CPU blade latch has been closed;

 

the switch is now fault tolerant.

Action:

None

(A1005.007D) (Canceling callhome edit mode as a result of a CPU switchover)

Meaning:

A CPU blade switchover occurred while a CallHome Edit session

 

was open. The CallHome Edit session was canceled.

Action:

Reopen the CallHome Edit session.

3-30

59060-05 A

Page 44
Image 44
Q-Logic FIRMWARE VERSION 7.4 manual A1005.0074 Blade seating is questionable, A1005.0075 Blade seating problem was resolved