Q-Logic FIRMWARE VERSION 7.4 manual A1004.0049 Eport Isolating due to Remote inactive

Models: FIRMWARE VERSION 7.4

1 84
Download 84 pages 32.06 Kb
Page 34
Image 34

3 – Event Messages Alarm Events

S

(A1004.0049) (Eport Isolating due to Remote inactive)

Meaning:

The remote switch is unresponsive, and the link has not been

 

brought up. The port will be isolated because the remote switch

 

failed to respond.

Action:

Investigate the remote switch for connection problems.

(A1004.0050) (Maximum hard zoning member limit exceeded, Reverting to soft zoning. Requires port reset.)

Meaning:

The maximum number of zone members associated with a port is

 

limited to 64. If this number is exceeded, the switch cannot enforce

 

hard zoning and will revert to soft zoning.

Action:

Reduce the number of zone members associated with the port and

 

reset the port.

(A1004.0051) (Blade IO blade_number isolated due to startup problem)

Meaning:

There is an internal communication issue with an IO blade. It will

 

be set down until it clears.

Action:

If this problem persists, contact your authorized maintenance

 

provider.

(A1004.0052) (Eport Isolating due to Switch Binding failure)

Meaning:

A device attempted to login as an inter-switch link, but that device

 

was not configured in the switch binding list.

Action:

Add the device to the switch binding list.

(A1004.0053) (Adding Denial of Service entry for source FC Address 0xaddress)

Meaning:

A number of frames from the indicated address have been

 

received. These frames are from a source that is not zoned with

 

the destination. A denial of service entry will be set up to discard

 

these frames.

Action:

Investigate the source at the specified Fibre Channel address.

(A1004.0054) (Eport Isolating due to Link to self)

Meaning:

Two ports on the same switch cannot be connected together.

Action:

Disconnect one or both ports.

(A1004.0055) (Chassis Interconnect cables misconfigured, see configuration guide for optimal setup)

Meaning:

Two SANbox 9000 switches are interconnected with

 

HyperStacking cables in a manner that is not supported.

Action:

Refer to the Installation Guide for information about how to connect

 

SANbox 9000 switches with HyperStacking cables.

3-20

59060-05 A

Page 34
Image 34
Q-Logic FIRMWARE VERSION 7.4 manual A1004.0049 Eport Isolating due to Remote inactive