3 – Event Messages Alarm Events

(A3002.0002) (Temp sensor sensor_name on blade slot_number reads value C - ALARM CLEARED)

Meaning:

The named blade has returned to the normal operating

 

temperature range.

Action:

None

(A3003.0001) (IOn) (Hardware error detected. Use 'show switch' for more info.)

Meaning:

A fatal hardware error was discovered during the

 

Power-On-Self-Test (POST) phase of startup. This switch is not

 

currently operational.

Action:

Enter the Show Post Log command to investigate.

(A3003.0002) (POST detected a fatal error the last time it ran and will be re-executed.)

Meaning:

A fatal hardware error was discovered from the previous

 

Power-On-Self-Test (POST). This switch is not currently

 

operational.

Action:

Enter the Show Post Log command to investigate.

(A3003.0003) (Diagnostics have detected a fatal error on the I/O blade in slot slot_number. The blade is not operational.)

Meaning:

Diagnostic testing has determined that there is a failure on

 

specified I/O blade. The blade did not pass the Power-On-Self-Test

 

(POST).

Action:

Enter the Show Post Log command to investigate.

(A3004.0001) (Non-fatal hardware error detected. Use 'show post log' for more info)

Meaning:

A non-fatal hardware error was discovered during the

 

Power-On-Self-Test (POST) phase of startup.

Action:

Enter the Show Post Log command to investigate.

(A3004.0002) (Diagnostics have detected a partial failure on the I/O blade in slot slot_number)

Meaning:

Diagnostic testing has determined that there is a partial failure on

 

specified I/O blade. Most likely, at least one of the ports did not

 

pass the Power-On-Self-Test (POST).

Action:

Enter the Show Post Log command to investigate.

(A3005.0001-000C) (value voltage sensor shows valueV - ALARM SET)

Meaning:

A switch voltage sensor on a SANbox 5000 series switch is

 

experiencing an out-of-range voltage condition.

Action:

Contact your authorized maintenance provider.