A

3 – Event Messages Informative Events

(I) (8400.002C) (Switch) (User login session session_ID user account_name has timed out)

Meaning:

A user login session has ended because of inactivity.

(I) (8400.0036) (Switch) (Hotreset not permitted at this time, try again later)

Meaning:

Conditions exist that will not allow a hotreset. Try again later.

(I)(8400.0037) (Switch) (VIEnable automatically set to False since MFSEnable has been set to True)

Meaning:

Setting the Set Config Port parameter MFSEnable to True

 

automatically sets the Set Config Port parameters VIEnable and

 

LCFEnable to False.

(I)(8400.0038) (Switch) (LCFEnable automatically set to False since MFSEnable has been set to True)

Meaning:

Setting the Set Config Port parameter MFSEnable to True

 

automatically sets the Set Config Port parameters VIEnable and

 

LCFEnable to False.

(I)(8400.0039) (Switch) (MFSEnable automatically set to False since VIEnable has been set to True)

Meaning:

Setting the Set Config Port parameter VIEnable to True

 

automatically sets the Set Config Port parameter MFSEnable to

 

False.

(I)(8400.003A) (Switch) (MFSEnable automatically set to False since LCFEnable has been set to True)

Meaning:

Setting the Set Config Port parameter LCFEnable to True

 

automatically sets the Set Config Port parameter MFSEnable to

 

False.

(I) (8400.003E) (Switch) (Readjusting TempMonitoringWarning from value C to value C)

Meaning:

The temperature threshold at which the switch issues a warning

 

alarm is being changed.

(I) (8400.0040) (Switch) (Readjusting TempMonitoringFailure from value C to value C)

Meaning:

The temperature threshold at which the switch issues a failure

 

alarm is being changed.

(I) (8400.0048) (Switch) (A CIM edit session has been canceled)

Meaning:

A Common Information Model (CIM) edit session has been

 

cancelled.

59060-05 A

3-67

Page 81
Image 81
Q-Logic FIRMWARE VERSION 7.4 manual Switch Hotreset not permitted at this time, try again later