Q-Logic FIRMWARE VERSION 7.4 manual That could not configure itself as an EPort

Models: FIRMWARE VERSION 7.4

1 84
Download 84 pages 32.06 Kb
Page 31
Image 31

A

3 – Event Messages Alarm Events

(A1004.0026) (Configured Domain ID domain_ID not available and Domain ID is locked on this switch)

Meaning:

An attempt was made to connect a switch to a fabric with a

 

conflicting domain ID, and the domain ID could not be reassigned.

Action:

Change the domain ID so that it is unique in the fabric, or disable

 

the domain ID lock so that the domain ID can be automatically

 

reassigned.

(A1004.0029) (No Switch capable of being Principal Switch. Reconfigure Principal Switch Priority.)

Meaning:

An E_Port isolated because the principal priority on all switches is

 

set to 254.

Action:

Configure one of the switches to be the principal switch by

 

changing the principal priority.

(A1004.002B) (Port port_number not configured for E-Port capability, reconfigure to G/GL to connect to remote switch)

Meaning:

An attempt was made by a remote switch to connect through a port

 

that could not configure itself as an E_Port.

Action:

Change the port type on the remote switch to G_Port or GL_Port.

(A1004.002D) (Non-interop Legacy switch setting prevents domain/port zoning)

Meaning:

Zone members involving switches of other vendors cannot be

 

defined by domain ID and port number when Interop Mode is

 

disabled and Legacy Address Formatting is enabled.

Action:

Disable (False) the Legacy Address Formatting, enable Interop

 

Mode, or reassign the zone members using a method other than

 

domain ID and port number.

(A1004.002F) (Request for Domain ID rejected, WorldWide Name (WWN) device_WWN not allowed to join fabric.)

Meaning:

The switch with the specified worldwide name is not allowed to join

 

the fabric.

Action:

Add the switch to a group in the active security set.

(A1004.0030) (Topology change, lost route to switch with domain ID domain_ID)

Meaning:

Connection to a switch in the fabric was lost.

Action:

Inspect switch connections and device hardware for proper

 

operation. Review accompanying alarms for other causes.

59060-05 A

3-17

Page 31
Image 31
Q-Logic FIRMWARE VERSION 7.4 manual That could not configure itself as an EPort