3 – Event Messages Alarm Events

(A1005.004E) (Attempts to login backend switch fail because backend switch does not support NPIV.)

Meaning:

The backend fabric switch does not support N_Port ID

 

Virtualization (NPIV), which in turn brings down the TF_Port.

Action:

Ensure that the backend fabric switch supports NPIV.

(A1005.004F) (Media device sensor is value units. Transitioning from state to state)

Meaning:

The specified sensor (temperature, voltage, TxBias, TxPower,

 

RxPower) has set a fault. The sensor reports its value (°Celsius,

 

volts, milliAmps, milliWatts) and transition states (low alarm, low

 

warning, normal, high warning, high alarm).

Action:

For the temperature sensor transitioning from low alarm to high

 

alarm, cool the system. For all other sensors transitioning from low

 

alarm to high alarm, replace the media.

(A1005.0050) (Media device device_name is value units. Transitioning from state to state)

Meaning:

The specified sensor (temperature, voltage, TxBias, TxPower,

 

RxPower) has cleared an existing fault. The sensor reports its

 

value (°Celsius, volts, milliAmps, milliWatts) and transition states

 

(low alarm, low warning, normal, high warning, high alarm).

Action:

None

(A1005.0051) (Canceling config edit mode as a result of a CPU switchover)

Meaning:

A CPU blade switchover occurred while a Config Edit session was

 

open. The Config Edit session was canceled.

Action:

Reopen the Config Edit session.

(A1005.0052) (Canceling IP ping as a result of a CPU switchover)

Meaning:

A CPU blade switchover occurred while an Ethernet ping was in

 

progress. The Ethernet ping was canceled.

Action:

Retry the Ping command.

(A1005.0053) (Canceling FC ping as a result of a CPU switchover)

Meaning:

A CPU blade switchover occurred while an Fibre Channel ping was

 

in progress. The Fibre Channel ping was canceled.

Action:

Retry the Fcping command.

(A1005.0054) (Canceling FC Trace Route as a result of a CPU switchover)

Meaning:

A CPU blade switchover occurred while an Fibre Channel trace

 

route was in progress. The trace route was canceled.

Action:

Retry the Fctrace command.