ELECTRICAL DATAKS57C2308/P2308/C2316/P2316

Table 14-2. D.C. Electrical Characteristics (Concluded)

(TA = – 40 °C to + 85 °C, VDD = 1.8 V to 5.5 V)

Parameter

Symbol

Conditions

 

Min

Typ

Max

Units

 

 

 

 

 

 

 

 

 

VLC0 Output

VLC0

TA = 25 øC

 

0.6 VDD

0.6 VDD

0.6 VDD +

V

voltage

 

 

 

 

0.2

 

0.2

 

VLC1 Output

VLC1

TA = 25 øC

 

0.4 VDD

0.4 VDD

0.4 VDD

 

voltage

 

 

 

 

– 0.2

 

+ 0.2

 

VLC2 Output

VLC2

TA = 25 øC

 

0.2 VDD

0.2 VDD

0.2 VDD

 

voltage

 

 

 

 

– 0.2

 

+ 0.2

 

Supply

IDD1 (2)

Main operating:

 

6.0 MHz

3.5

8

mA

Current (1)

 

VDD = 5 V ± 10%

 

4.19 MHz

 

2.5

5.5

 

 

 

CPU = fx/4

 

 

 

 

 

 

 

 

SCMOD = 000B

 

 

 

 

 

 

 

 

crystal oscillator

 

 

 

 

 

 

 

 

C1 = C2 = 22pF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VDD = 3 V ± 10%

 

6.0 MHz

 

1.6

4

 

 

 

 

 

4.19 MHz

 

1.2

3

 

 

IDD2 (2)

Main Idle mode;

 

6.0 MHz

1.0

2.5

 

 

 

VDD = 5 V ± 10%

 

4.19 MHz

 

0.9

2.0

 

 

 

CPU = fx/4

 

 

 

 

 

 

 

 

SCMOD = 000B

 

 

 

 

 

 

 

 

crystal oscillator

 

 

 

 

 

 

 

 

C1 = C2 = 22pF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VDD = 3 V ± 10%

 

6.0 MHz

 

0.5

1.0

 

 

 

 

 

4.19 MHz

 

0.4

0.8

 

 

IDD3

Sub operating:

 

15

30

µA

 

 

VDD = 3 V ± 10%

 

 

 

 

 

 

 

CPU = fxt/4

 

 

 

 

 

 

 

SCMOD = 1001B

 

 

 

 

 

 

 

32 kHz crystal oscillator

 

 

 

 

 

 

IDD4

Sub Idle mode;

 

6

15

 

 

 

VDD = 3 V ± 10%

 

 

 

 

 

 

 

CPU = fxt/4, SCMOD = 1101B

 

 

 

 

 

 

32 kHz crystal oscillator

 

 

 

 

 

 

IDD5

Stop mode;

 

0.5

3

 

 

 

VDD = 5 V ± 10%

 

 

 

 

 

 

 

CPU = fxt/4, SCMOD = 1101B

 

 

 

 

 

IDD6 (3)

Stop mode;

 

 

 

 

 

 

 

VDD = 5 V ± 10%

 

 

 

 

 

 

 

CPU = fx/4, SCMOD = 0100B

 

 

 

 

 

NOTES:

1.D.C. electrical values for supply current (IDD1 to IDD6) do not include current drawn through internal pull-up resistors and through LCD voltage dividing resistors.

2.Data includes the power consumption for sub-system clock oscillation.

3.When the system clock mode register, SCMOD, is set to 0100B, the sub-system clock oscillation stops. The main-system clock oscillation stops by the STOP instruction.